Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Authors

Department of Mechanical Engineering, West Tehran Branch, Islamic Azad University, Tehran, Iran

Abstract

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary condition at the aorta entrance using magnetic resonance angiography (MRA) and the finite volume method (FVM), as well as a large eddy simulation (LES) turbulence model. The results were validated by comparing the blood flow static pressure from the numerical simulation to a clinical measurement available in the literature. The Inclusion of the turbulence model in the solution resulted in a static pressure for the heart’s normal function at the coarctation that agreed very well with the clinical measurement; the difference was just 0.39 mmHg. Therefore, the study confirmed the validity of the simulation results, the assumption that a turbulence regime exists inside an aorta with a coarctation, and the efficiency of the LES turbulence model for simulating cardiovascular flows.

Keywords


1.     Morgagni, J., "De sedibus et causis morborum, 1761", Classics of cardiology. Malabar, Fla: Robert E. Kreiger,  (1983), 186-187.
2.     Jain, M., Sharma, G. and Singh, R., "Mathematical modelling of blood flow in a stenosed artery under mhd effect through porous medium", International Journal of Engineering, Transactions B,  Vol. 23, No. 3-4, (2010), 243-251.
3.     Kumar, S. and Kumar, D., "Oscillatory mhd flow of blood through an artery with mild stenosis (research note)", International Journal of Engineering-Transactions A: Basics,  Vol. 22, No. 2, (2008), 125-130.
4.     Jain, M., Sharma, G. and Sharma, S.K., "A mathematical model for blood flow through narrow vessels with mild stenosis", International Journal of Engineering, Transactions B: Applications,  Vol. 22, No. 1, (2009), 99-106.
5.     Gupta, A.K., "Performance model and analysis of blood flow in small vessels with magnetic effects", International Journal of Engineering-Transactions A: Basics,  Vol. 25, No. 2, (2012), 189-196.
6.     Crosetto, P., Reymond, P., Deparis, S., Kontaxakis, D., Stergiopulos, N. and Quarteroni, A., "Fluid–structure interaction simulation of aortic blood flow", Computers & Fluids,  Vol. 43, No. 1, (2011), 46-57.
7.     Jahangiri, M., Saghafian, M. and Sadeghi, M.R., "Numerical study of turbulent pulsatile blood flow through stenosed artery using fluid-solid interaction", Computational and Mathematical Methods in Medicine,  Vol. 2015, (2015), Article ID 515613.
8.     Yin, J., Xiang, Y. and Dou, Q., "Three-dimensional reconstruction and numerical simulation of blood flow in human thoracic aortic", in Bioinformatics and Biomedical Engineering (iCBBE), 2010 4th International Conference on, IEEE., (2010), 1-4.
9.     Manimaran, R., "Cfd simulation of non-newtonian fluid flow in arterial stenoses with surface irregularities", World Academy of Science, Engineering and Technology,  Vol. 73, No. 5, (2011), 804-809.
10.   Wang, X., Walters, D.K., Burgreen, G.W. and Thompson, D.S., "Traditional cfd boundary conditions applied to blood analog flow through a patient-specific aortic coarctation", in International Workshop on Statistical Atlases and Computational Models of the Heart, Springer., (2013), 118-125.
11.   Sotelo, J., Urbina, J., Valverde, I., Tejos, C., Irarrázaval, P., Hurtado, D.E. and Uribe, S., "Quantification of wall shear stress using a finite-element method in multidimensional phase-contrast mr data of the thoracic aorta", Journal of Biomechanics,  Vol. 48, No. 10, (2015), 1817-1827.
12.   Arokiaraj, M., De Beule, M. and De Santis, G., "A novel sax-stent method in treatment of ascending aorta and aortic arch aneurysms evaluated by finite element simulations", JMV-Journal de Médecine Vasculaire,  Vol. 42, No. 1, (2017), 39-45.
13.   Lilly, D.K., "A proposed modification of the germano subgrid‐scale closure method", Physics of Fluids A: Fluid Dynamics,  Vol. 4, No. 3, (1992), 633-635.